H2C0 fuel cells · Sizing and enquiry

Size your fuel cell system, then ask us for a quote.

Tell us about your load, backup hours and site. The calculator gives an indicative H2C0 system size, hydrogen use and storage, and sends your enquiry to our fuel cell team with the numbers attached.

Umagine Hydrogen H2C0 fuel cell sizing · inputs
Application
Load
Average load
kW
Peak load
kW
Outage hours per day
h
Hydrogen
Hydrogen on site
days
Cylinder pressure
Cylinder size
L
Site
Altitude
m
Highest ambient
°C
Lowest ambient
°C
System
Electrical output
Redundancy
Sizing assumptions
Output per kg H₂
kWh/kg
Sizing margin
%
Battery bridging
min
Storage pressure
bar
1 × 5.0 kW liquid-cooled1.71 kg H₂ a day12.0 kg on site · 19 cylindersFull sizing ↓
Umagine Hydrogen · UHPLH2C0 fuel cellsFuel cell sizingumagine.co.in/fuel-cell-calculator.html
Indicative H2C0 system · Umagine Hydrogen (UHPL)

1 × 5.0 kW liquid-cooled fuel cell

5.0 kW installed, 4.8 kW available at your site, DC output.

H2C0 fuel cell rating
UHPL
5.0kW
1 × 5.0 kW modules · liquid-cooled
Hydrogen per day
UHPL
1.71kg
0.29 kg/h at peak load · 626 kg a year
Hydrogen on site
UHPL
12.0kg
19 cylinders of 50 L at 200 bar · 13.3 kg installed
Battery buffer
UHPL
1.5kWh
15 min at 4.0 kW for start-up and load steps
Running time
UHPL
2,920h / year
24.0 kWh a day · 8.8 MWh a year
Liquid-cooled systems come with 415 VAC three-phase output as standard; a DC output, such as a 48 V telecom bus, can be configured.
Site derating 5%: 5.0 kW nameplate delivers 4.8 kW at 300 m and 45 °C.
How Umagine Hydrogen sizes it
Peak load plus sizing margin4.4 kW
4.0 kW × 1.1
Site derating−5%
300 m altitude and 45 °C
Nameplate rating needed4.6 kW
Standard H2C0 modules1 × 5.0 kW
Liquid-cooled series, 5 kW to 2 MW
Energy a day24.0 kWh
3.0 kW × 8.0 h
Hydrogen a day1.71 kg
at 14.0 kWh per kg
Usable hydrogen for 7 days12.0 kg
13.3 kg stored, 90% usable
Per cylinder0.70 kg
50 L at 200 bar, 25 °C, real gas
Indicative sizing by Umagine Hydrogen (UHPL) for a first conversation, not a design. Output is derated by about 1% per 100 m above 1,000 m and 1% per °C above 40 °C; modules are picked from the standard H2C0 sizes. Hydrogen use assumes the average load for the hours given; cylinders are sized with real-gas (van der Waals) hydrogen at 25 °C. A detailed proposal needs your load profile, site data and hydrogen logistics, which is what the enquiry starts.
Send this configuration to our fuel cell team ↓
Enquiry

Get a proposal for this configuration.

The sizing above is attached automatically. Add your contact details and anything the calculator cannot know, and our fuel cell team will come back to you with a proposal, or with questions.

Fills in the contact details from a photo of the card. The photo is read on this device and is not uploaded.
Or email contact@umagine.co.in